Lifts
Alignment Lifts & Systems
Tire Changers
Wheel Balancers
Frame Machines
Other Shop Equipment
Daytona Automotive Equipment About Daytona Daytona Frequently Asked Questions Daytona Distributors Information Contact Daytona Daytona Home Page
Daytona Automotive Equipment
Daytona Automotive Equipment
OTHER SHOP EQUIP
Air Compressors
Recovery, Recycling, Recharg.
UV Refrig. Leak Detection Kits
Pro Pipe Bender
Brake Lathes
Nitrogen Tire Inflator

RECOVERY, RECYCLING, RECHARGING EQUIPMENT

THIS EQUIPMENT HAS BEEN CERTIFIED BY UNDERWRITERS
LABORATORIES INC. TO MEET EPA’S MINIMUM REQUIREMENTS
FOR RECOVERY EQUIPMENT INTENDED FOR USE WITH ALL
APPLIANCES CONTAINING REFRIGERANT 12, 22,
500, AND 134a. UL CONTROL NUMBER 2HA5

 

  • Automatic programmable charging
  • Lo side or Hi side or Hi & LO side charging
  • Non-restrictive heavy duty ball valve control system
  • On board HI and LO gauges and valves for manifold function
  • 16 cubic inch filter drier with moisture indicator
  • .7 micron oil separator filter to collect and measure oil removed from the mobile A/C system
  • 1” heavy duty tubular steel frame with powder coated steel cabinetry
  • Large 10” pneumatic wheels with 4.5” swivel casters for easy manoeuvrability
  • R134a couplers and refill adaptors
  • Can be dedicated to one of several refrigerants.  See specification list for approved refrigerants
  • Built in condenser for high ambient temperature operation
  • Built in evaporator to protect the compressor against flood-back
  • On board 50lb recovery tank

PUMP DOWN VALVE CAN BE SUPPLIED
FOR MULTI REFRIGERANT OPERATION

Specifications:

Compressor Type: 1/3 HP reciprocating compressor
Dimensions : 22”W x 24.5”D x 42”H
Operating Range: 0°C (32°F) to 49°C (120°F)
Power Source: 115 VAC 60Hz 1Ph
Power consumption: 500 W
Suction Pressure Gauge : -30 inch Hg to 125 PSIG
Discharge Pressure Gauge: 0 to 500 PSIG
Filtration: 16 cubic inch filter drier w/ moisture indicator, .7-micron oil separator
Manual Control Valves: Ball valves control HI, LO, Recover, and Vacuum
Charging Valve: 12 VDC Solenoid Valve
Construction: 1” heavy-duty tubular frame construction – 10” pneumatic wheels
Overload protection: 15A Thermal Breaker
High Pressure shut off : 30 bar (450 psig)
Refrigerants*: R134a, R12, R22, R502, R402a, R401a, R407c, R409a


 

Printer Friendly Page